45 DEGREE STOP ADJUSTMENT
1. Loosen the bevel clamp handle
and set the saw head as far to the
left as possible (this should be the
45° angle)
2. Place a 45° set square on the
table and up against the blade.
NOTE: Do not touch the tips of the
blade teeth with the square.
3. Turn the 45° adjustment stop screw in or out until the blade is at 45° to the
table as measured with the square.
4. Adjust the bevel point if required as shown in point 6 above.